Laddomat MR 10

Control Equipment

Laddomat MR 10

  • Sys 10 - Burner control. To control the start / stop of burners (e.g. oil or pellets) for batch loading of tank / tanks. This gives long running times and fewer starts / stops of the burner
  • Sensors that are not used for control can be used for temperature reading in a separate menu

Product description

Charging unit MR 10 is a burner control for batch charging of tank / tanks. The control centre has a separate connection centre (AC) with a total of 3 relays and 4 sensor inputs. All settings are made in the separate control panel.

Laddomat MR, complete.

  • Charging package Laddomat 11-30 or Laddomat 11-200, with pump and ball valves.
  • 2 pcs 3-bulbs diving pipe for bulbs with D = 6 mm. R15, L = 150 mm.
  • 3 sensor holders and cable ties for pipe mounting.


Function Sys10

  • The burner starts when the sensor at the top of the tank gets cold and stops when the sensor at the bottom of the tank gets hot. The charge pump is started if the sensor in the boiler gets hot, or immediately when the burner is started, so-called "Constant" operation.

Similar products

Laddomat MR 50

Laddomat MR 50

  • The extra tanks can be placed far away from the main tank
  • No involuntary circulation between the thoughts
  • Piping can be done with a smaller dimension = simpler and cheaper installation
  • Effective layering = large accumulation capacity
  • Optimisation of possible solar heat
Laddomat MR

Laddomat MR

  • A Laddomat MR can control in many different ways
  • It is a great product to have in stock because it is easier to learn the settings because they have one and the same controls, connections and adjustments that can be made
Laddomat MR 40

Laddomat MR 40

  • Charging machine MR 40 is a charging package for boiler with built-in water heater and shunt
  • The thermal 3-way valve has 2 non-return valves so that the flow can go in two directions
  • The control centre has a separate connection centre (AC) with a total of 3 relays and 4 sensor inputs
  • All settings are made in the separate control panel
Laddomat MR 30

Laddomat MR 30

  • Reduces culvert losses
  • Increases accumulation capacity
  • Automatic start of additional heat when the main tank is emptied
  • Check valve and automatic stop of the charge pump guarantee that the additional heat does not heat the main tank
  • It is possible to adapt to drive heat back to the main tank, e.g. if the solar loop is in the slave tank